J2320, J2350, J4350, and J6350 Services RouterGetting Started GuideRelease 9.2Juniper Networks, Inc.1194 North Mathilda AvenueSunnyvale, California 94

Strany 2

Power Guidelines, Requirements, and Specifications ...107Site Electrical Wiring Guidelines ...

Strany 3 - End User License Agreement

For more information about the TIM516, see the Avaya manual Hardware Descriptionand Reference for Avaya Communication Manager.TIM518 Analog Telephony

Strany 4

For pinouts of cable connectors for the TIM518, see “TIM518 ConnectorPinout” on page 244.To install or remove an Avaya VoIP module, see “Replacing a P

Strany 5 - Abbreviated Table of Contents

NOTE: The TIM521 does not support BRI stations or combining both B-channelstogether to form a 128-Kbps channel. Over a 16-Kbps channel, called the D-

Strany 6

Chapter 4Services Router User Interface OverviewYou can use two user interfaces to monitor, configure, troubleshoot, and manage aServices Router—the J

Strany 7

Edit the configuration in a text file. Upload a configuration file.The J-Web interface also allows you to manage configuration history and set ares

Strany 8

Using the J-Web InterfaceThis section contains the following topics: Starting the J-Web Interface on page 83 J-Web Layout on page 83 Elements of th

Strany 9 - Table of Contents ■ ix

Top pane—Displays identifying information and links. Main pane—Location where you monitor, configure, diagnose, and manage theServices Router by en

Strany 10 - Table of Contents

Top Pane ElementsThe top pane comprises the elements shown in Figure 49 on page 85.Figure 49: Top Pane Elements Juniper Networks logo—Link to http://w

Strany 11 - Table of Contents ■ xi

Figure 50: Main Pane Elements Help (?) icon—Displays useful information when you move the cursor over thequestion mark. This help displays field-spec

Strany 12

Figure 51: Side Pane Elements Subtask—Displays options related to the selected task in the J-Web taskbar. Configuration hierarchy—For the J-Web conf

Strany 13 - Table of Contents ■ xiii

Configuring Basic Settings with a Configuration Editor ...147Verifying Basic Connectivity ...

Strany 14 - Part 5 Index

The path displayed in the top right corner of each page provides a context. Use thispath to see your location in a configuration hierarchy. Clicking a

Strany 15 - About This Guide

Table 49: Key J-Web Edit Configuration Buttons (continued)ButtonFunctionCancelClear the entries you have not yet applied to the candidate configuratio

Strany 16 - How to Use This Guide

Figure 52: CoS Help PageJ-Web SessionsYou establish a J-Web session with the Services Router through an HTTP-enabled orHTTPS-enabled Web browser. The

Strany 17 - Document Conventions

Using the Command-Line InterfaceThis section contains the following topics: CLI Command Hierarchy on page 91 Starting the CLI on page 92 CLI Operat

Strany 18

intervening space), you see a list of commands that match the partial name youtyped.Starting the CLITo start the CLI:1. Establish a connection with th

Strany 19

set Set CLI properties, date/time, craft interface message show Show system information ssh Star

Strany 20

insert Insert a new ordered data element load Load configuration from ASCII file quit Quit from this

Strany 21 - Requesting Technical Support

Table 50: CLI Editing KeystrokesKeyboard SequenceActionTask CategoryCtrl-bMove the cursor back one character.Move the cursor.Esc bMove the cursor back

Strany 22

To complete a command or option that you have partially typed, press Tab orSpacebar. If the partially typed letters uniquely identify a command, the c

Strany 23 - J-series Overview

When you enter the help commands described in Table 51 on page 97, the CLIdisplays usage guidelines and summary information for configuration statemen

Strany 24 - 2 ■ J-series Overview

Replacing PIM Cables ...175Removing PIM Cables ...

Strany 25 - Overview of Services Routers

user@host> set cli ?Possible completions: complete-on-space Set whether typing space completes current word directory Set working d

Strany 26

Table 52: Configuring the CLI Environment (continued)OptionsDefault SettingCLI CommandEnvironmentFeatureTo change the number of charactersdisplayed on

Strany 27

100 Using the Command-Line InterfaceJ2320, J2350, J4350, and J6350 Services Router Getting Started Guide

Strany 28

Part 2Installing a Services Router Preparing for Router Installation on page 103 Installing and Connecting a Services Router on page 117 Establishi

Strany 29 - IPv6 routing and forwarding

102 Installing a Services RouterJ2320, J2350, J4350, and J6350 Services Router Getting Started Guide

Strany 30

Chapter 5Preparing for Router InstallationBefore installing a J-series Services Router, make sure that your site has the properoperating environment a

Strany 31 - Ethernet Switching

Rack RequirementsJ-series Services Routers must be installed in a rack. Many types of racks areacceptable, including front-mount racks, four-post (tel

Strany 32

The J2320 chassis height of 1.75 in. (4.45 cm) equals 1 U. The J2350 chassis heightof 2.61 in. (6.63 cm) equals 1.5 U. Each U is a standard rack unit

Strany 33 - Administration

Router Environmental TolerancesTable 53 on page 106 specifies the environmental conditions required for normalServices Router operation. In addition,

Strany 34

Then, use a Type C fire extinguisher, which uses noncorrosive fire retardants, toextinguish the fire. For more information about fire extinguishers, s

Strany 35 - System Overview

Part 4 J-series Requirements and SpecificationsChapter 13 Network Cable Specifications and Connector Pinouts 223Serial PIM Cable Specifications ...

Strany 36

Site Electrical Wiring GuidelinesWARNING: Certain ports on the router are designed for use as intrabuilding(within-the-building) interfaces only (Type

Strany 37 - Chapter 2: System Overview

CAUTION: To comply with intrabuilding lightning/surge requirements, intrabuildingwiring must be shielded, and the shield for the wiring must be ground

Strany 38

Detachable AC power cords, each 2.5 m (approximately 8 ft) long, are supplied withthe Services Router. The appliance coupler at the female end of the

Strany 39

For information about the AC power supply, see “J2320 and J2350 Services RouterHardware Features” on page 13 and “J4350 and J6350 Services Router Hard

Strany 40 - J2320 and J2350 Midplane

NOTE: Power cords and cables must not block access to router components or drapewhere people might trip on them.For information about the DC power sup

Strany 41 - J2320 and J2350 Front Panel

Table 57: J-series PIM Power Consumption and Heat DissipationTokensPIM Abbreviationin JUNOS CLIModel NumberNameHeatHigh PowerLow Power8–81xSFP uPIMJX

Strany 42 - Power Button and POWER LED

Table 57: J-series PIM Power Consumption and Heat Dissipation (continued)TokensPIM Abbreviationin JUNOS CLIModel NumberNameHeatHigh PowerLow Power162

Strany 43 - ALARM LED

Network Cable SpecificationsThe Services Router supports interfaces that use various kinds of network cable. Forinformation about the type of cable us

Strany 44 - RESET CONFIG Button

116 Site Preparation ChecklistJ2320, J2350, J4350, and J6350 Services Router Getting Started Guide

Strany 45 - AUX Port

Chapter 6Installing and Connecting a ServicesRouterMake the appropriate preparations and verify the J-series equipment before installinga J-series Ser

Strany 46 - J2350 Power System

Grounded Equipment Warning ...260Warning Statement for Norway and Sweden ...

Strany 47

For J4350 and J6350 Services Routers—Mounting brackets and screws(provided), number 2 Phillips screwdriver, and mounting screws appropriatefor your

Strany 48

Installing J2320 and J2350 RoutersWARNING: DC-powered Services Routers are intended for installation only in arestricted access location.You can cente

Strany 49 - J4350 and J6350 Chassis

3. Align the top hole in each mounting bracket with a hole in each rack rail as shownin Figure 56 on page 120 and Figure 57 on page 120, making sure t

Strany 50

You can center-mount or front-mount the J4350 and J6350 Services Routers in arack. In general, a center-mount rack is preferable to a front-mount rack

Strany 51

Figure 59: Attaching Center Screw to the Rack3. Lift the router and insert the larger elliptical openings in the mounting bracketsonto the partially i

Strany 52

Figure 61: Completing the InstallationConnecting Interface Cables to Services RoutersYou connect the interfaces installed in the Services Router to va

Strany 53 - J4350 and J6350 Boot Devices

For J2320 and J2350 Services Routers—The grounding cables must be, atminimum, 14 AWG single-strand wire cable. The grounding lug must be aring-type,

Strany 54 - J4350 and J6350 Front Panel

c. With a Phillips screwdriver, remove the screw and washer from the PEMnuts at the grounding point on the rear of the chassis.d. Place the grounding

Strany 55

Figure 63: Connecting AC Power to the J2350 Services RouterFigure 64: Connecting AC Power to the J4350 or J6350 Services RouterConnecting DC PowerCAUT

Strany 56

1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, andconnect the strap to the ESD point on the chassis. For more informat

Strany 57

About This GuideThis preface provides the following guidelines for using the J2320, J2350, J4350, andJ6350 Services Router Getting Started Guide: Obj

Strany 58 - J4350 Power System

overtighten. Apply between 8 lb-in. (0.9 Nm) and 9 lb-in. (1.02 Nm) of torqueto the screw.f. Using the other removed screw, secure the negative (–) DC

Strany 59 - J6350 Power System

Figure 66: Connecting DC Power to the J4350 or J6350 Services RouterPowering a Services Router On and OffTo power on a Services Router, press the powe

Strany 60

130 Powering a Services Router On and OffJ2320, J2350, J4350, and J6350 Services Router Getting Started Guide

Strany 61 - Software Overview

Chapter 7Establishing Basic ConnectivityThe JUNOS software is preinstalled on the Services Router. When the router ispowered on, it is ready to be con

Strany 62 - JUNOS Software Processes

Table 60: Basic Connectivity Terms (continued)DefinitionTermPackets destined for IP addresses not identified in the routing table aresent to the defau

Strany 63 - User Interfaces

Root PasswordThe root user has complete privileges to configure the Services Router, and managefiles in the router's file system. Initially, the

Strany 64 - 42 ■ Software Overview

are added to the configuration to resolve hostnames in the order in which you listthem.If you plan to include your router in several domains, you can

Strany 65 - PIM and VoIP Module Overview

After the initial configuration is complete, you can attach the built-in Ethernet portthat you are using for management purposes to the management net

Strany 66 - PIM and VoIP Module Terms

If the router is operating in a Common Criteria environment, see the SecureConfiguration Guide for Common Criteria and JUNOS-FIPS.SSH also allows you

Strany 67

A management device, such as a PC or laptop, with a serial port and anasynchronous terminal application (such as Microsoft WindowsHyperterminal) An

Strany 68 - Field-Replaceable PIMs

Network administrators who install, configure, and manage products of JuniperNetworksPersonnel operating the equipment must be trained and competent

Strany 69

7. Turn on the power to the management device. The router assigns an IP addressto the management device within the 192.168.1.0/24 subnetwork if the de

Strany 70 - 48 ■ Field-Replaceable PIMs

Figure 68: Connecting to the Gigabit Ethernet Port on J4350 and J6350 RoutersConnecting to the CLI LocallyIf you plan to use the CLI to configure the

Strany 71

8. Configure the port settings as follows: Bits per second: 9600 Data bits: 8 Parity: None Stop bits: 1 Flow control: None9. Power on the router

Strany 72 - 50 ■ Field-Replaceable PIMs

Figure 70: Connecting to the Console Port on J4350 and J6350 RoutersConnecting to the CLI RemotelyYou can connect to the CLI from a remote location th

Strany 73 - Field-Replaceable PIMs ■ 51

3. From the PC or laptop computer, start your asynchronous terminal emulationapplication (such as Microsoft Windows Hyperterminal) and select the COM

Strany 74 - 1-Port Gigabit Ethernet ePIMs

Connecting to the CLI at the User EndTo remotely connect to the CLI through a dial-up modem connected to the consoleport on the router:1. At your remo

Strany 75 - Field-Replaceable PIMs ■ 53

Figure 71: Set Up Quick Configuration PageBefore you configure the router, gather the information described in “Before YouBegin” on page 136.To config

Strany 76 - 54 ■ Field-Replaceable PIMs

To cancel your entries and return to the Quick Configuration page, clickCancel.NOTE: After initial configuration is complete, the Services Router st

Strany 77 - Dual-Port Serial PIM

Table 61: Set Up Quick Configuration Summary (continued)Your ActionFunctionField To immediately set the time using the NTP server,click Set Time via N

Strany 78 - Dual-Port T1 or E1 PIM

Configuring Basic Settings with a Configuration EditorTo establish basic connectivity on a Services Router, you identify the router, connectthe router

Strany 79 - Field-Replaceable PIMs ■ 57

more extensive configuration, use the J-Web configuration editor or CLI configurationmode commands.To monitor, diagnose, and manage a router, use the

Strany 80 - 58 ■ Field-Replaceable PIMs

3. If you are using the J-Web interface, click Commit to view a summary of yourchanges, then click OK to commit the configuration. If you are using th

Strany 81 - T3 or E3 PIM

Table 63: Configuring Basic Settings (continued)CLI Configuration EditorJ-Web Configuration EditorTaskSet the address of the NTP server.For example:se

Strany 82 - Dual-Port Fast Ethernet PIM

Table 63: Configuring Basic Settings (continued)CLI Configuration EditorJ-Web Configuration EditorTask1.Delete the existing IP address:delete ge-0/0/0

Strany 83 - 4-Port Fast Ethernet ePIM

}services {}ntp {server 10.148.2.21;}}interfaces {ge-0/0/0 {unit 0 {family inet {address 192.168.1.1/24;}}}lo0 {unit 0 {family inet {address 172.16.1.

Strany 84 - 4-Port ISDN BRI PIMs

152 Displaying Basic Connectivity ConfigurationsJ2320, J2350, J4350, and J6350 Services Router Getting Started Guide

Strany 85 - Figure 37: ISDN BRI U PIM

Chapter 8Configuring Secure Web AccessYou can manage a Services Router remotely through the J-Web interface. Tocommunicate with the router, the J-Web

Strany 86 - ADSL PIM

Table 64: Secure Web Access Terms (continued)DefinitionTermProtocol similar to HTTP with an added encryption layer that encrypts and decryptsuser page

Strany 87 - G.SHDSL PIM

Obtain an SSL certificate from a trusted signing authority. See “Generating SSLCertificates” on page 155.Generating SSL CertificatesTo enable secure

Strany 88 - Avaya VoIP Modules

Figure 72: Quick Configuration Secure Access PageTo configure Web access settings in the J-Web interface:1. Enter information into the Secure Access Q

Strany 89 - Avaya VoIP Module Summary

3. To verify that Web access is enabled correctly, connect to the router using oneof the following methods: For HTTP access—In your Web browser, type

Strany 90 - 68 ■ Avaya VoIP Modules

Table 3: Text and Syntax Conventions (continued)ExamplesDescriptionConventionConfigure the machine’s domain name:[edit]root@# set system domain-namedo

Strany 91 - Avaya VoIP Modules ■ 69

Table 65: Secure Access Quick Configuration Summary (continued)Your ActionFunctionFieldTo enable HTTPS on all interfaces, select the EnableHTTPS on Al

Strany 92 - 70 ■ Avaya VoIP Modules

Table 66: Configuring a Secure Web Access (continued)CLI Configuration EditorJ-Web Configuration EditorTaskEnterset certificates local new load-key-fi

Strany 93 - J2350 Services Router

local {new {"-----BEGIN RSA PRIVATE KEY-----\nMIICXQIBAAKBgQC/C5UI4frNqbiqPwbTiOkJvqoDw2YgYse0Z5zzVJyErgSg954T\nEuHM67Ck8hAOrCnb0YO+SYY5rCXLf4+2s

Strany 94 - 72 ■ Avaya VoIP Modules

Chapter 9Installing and Managing J-series LicensesTo enable some JUNOS software features on a J-series Services Router, you mustpurchase, install, and

Strany 95 - Avaya VoIP Modules ■ 73

message after it commits the configuration rather than failing to commit it becauseof a license violation.Software Feature LicensesEach feature licens

Strany 96 - 74 ■ Avaya VoIP Modules

Managing J-series Licenses with the J-Web InterfaceTo manage licenses with the J-Web interface, you perform the following tasks: Adding New Licenses

Strany 97 - Table 40: LEDs for TIM510

Adding New Licenses with the J-Web InterfaceTo add a new license key on a Services Router with the J-Web license manager:1. In the J-Web interface, se

Strany 98 - 76 ■ Avaya VoIP Modules

3. Select Save it to disk and specify the file to which the license keys are to bewritten.4. Go on to “Verifying J-series License Management” on page

Strany 99 - Table 44: LEDs for TIM516

Saving License Keys with the CLITo save the licenses installed on the Services Router to a file with the CLI:1. Enter operational mode in the CLI.2. T

Strany 100 - 78 ■ Avaya VoIP Modules

Each license is present. Licenses are listed in ascending alphanumeric order bylicense ID. The feature for each license is the expected feature. Th

Strany 101 - Table 46: LEDs for TIM518

documentation of the statements and commands described in J-series guides, seethe JUNOS software manuals listed in Table 4 on page xix.Table 4: J-seri

Strany 102 - 80 ■ Avaya VoIP Modules

qq53lu qcx4vm ydakcs t3yyh2 v5mqG03000002224 aeaqea qkjjhd ambrha 3tkqkc ayargb zicik6 nv6jck btlxao 2trfyq 65cdou r5tbof l4u

Strany 103 - Chapter 4

Part 3Maintaining Services Router Hardware Replacing Hardware Components on page 171 Troubleshooting Hardware Components on page 209 Contacting Cus

Strany 104 - Before You Begin

170 Maintaining Services Router HardwareJ2320, J2350, J4350, and J6350 Services Router Getting Started Guide

Strany 105 - Using the J-Web Interface

Chapter 10Replacing Hardware ComponentsBecause many of the Services Router's hardware components are field-replaceableunits (FRUs), you can remov

Strany 106 - Figure 48: J-Web Layout

Table 69: Tools and Parts RequiredComponentsTool or PartAllElectrostatic bag or antistatic matAllElectrostatic discharge (ESD)grounding wrist strapPIM

Strany 107 - Main Pane Elements

CAUTION: Do not hot-swap PIMs. Failure to power off the router before removingor installing a PIM might result in damage to the hardware.Figure 73: Re

Strany 108 - Side Pane Elements

Installing a PIMCAUTION: Do not hot-swap PIMs. Failure to power off the router before removingor installing a PIM might result in damage to the hardwa

Strany 109 - Figure 51: Side Pane Elements

6. If necessary, arrange the cables to prevent them from dislodging or developingstress points: Secure each cable so that it is not supporting its ow

Strany 110

3. Arrange the cable as necessary to prevent it from dislodging or developing stresspoints: Secure the cable so that it is not supporting its own wei

Strany 111 - Getting J-Web Help

5. With a Phillips screwdriver remove the flat head screws from the rear and sidesof the chassis.6. Position the router so that you face the front pan

Strany 112 - J-Web Sessions

This product includes the Envoy SNMP Engine, developed by Epilogue Technology, an Integrated Systems Company. Copyright © 1986-1997, EpilogueTechnolog

Strany 113 - CLI Command Hierarchy

Table 4: J-series Guides and Related JUNOS Software Publications (continued)Corresponding JUNOS Software ManualChapter in a J-series Guide JUNOS MPLS

Strany 114 - CLI Operational Mode

Figure 77: Matching the Chassis Slots and Tabs3. Lower the cover fully onto the base, and slide it so that the front tabs match thefront slots and the

Strany 115 - CLI Configuration Mode

Figure 78: Location of J2320 and J2350 Internal Compact FlashTo replace the internal compact flash:1. Place an electrostatic bag or antistatic mat on

Strany 116 - CLI Basics

Figure 79: Removing the J2320 or J2350 Internal Compact Flash9. Place the compact flash on the antistatic mat or in the electrostatic bag.10. With the

Strany 117 - Command Completion

Replacing Internal Compact Flashes on J4350 and J6350 RoutersThe internal compact flash is installed in a slot on the bottom of the J4350 or J6350chas

Strany 118 - Online Help

Figure 82: Alternative Horizontal Orientation of J4350 and J6350 Compact FlashTo replace the compact flash:1. Place an electrostatic bag or antistatic

Strany 119 - Table 51: help Commands

Figure 83: Removing the J4350 or J6350 Compact Flash8. Place the compact flash on the antistatic mat or in the electrostatic bag.9. Slide the new comp

Strany 120

12. Replace the power cord or cable.13.Press and release the power button to power on the router. Verify that the POWERLED lights steadily.Replacing E

Strany 121

Skip this step, if the router did not boot from the external compact flash (seestep 1).5. With a Phillips screwdriver, loosen the pan head screws that

Strany 122

12. Tighten the pan head screws that secures the compact flash slot cover to therear of the chassis.13. Plug the power cord into the power supply.14.P

Strany 123 - Installing a Services Router

1.Verify the device that the router used to boot, by running the show system storagecommand from the CLI. For example:user@host> show system storag

Strany 124

Table 4: J-series Guides and Related JUNOS Software Publications (continued)Corresponding JUNOS Software ManualChapter in a J-series Guide JUNOS Syste

Strany 125 - Chapter 5

3. Insert the USB storage device into the USB port. If the USB storage device doesnot easily slide into the port, it might not be oriented correctly.

Strany 126 - Rack Requirements

Figure 89: J4350 and J6350 DRAM LocationTo modify the DRAM configuration, use the following procedures: Removing a DRAM Module on page 189 Installin

Strany 127 - Rack Requirements ■ 105

Figure 90: Installing or Replacing DRAM ModulesInstalling a DRAM ModuleJ2320, J2350, J4350 and J6350 Services Routers support 256-MB and 512-MB DRAMmo

Strany 128 - Fire Suppression

5. Pressing firmly on both ends, push the module into the slot until the ejectorsclick into the closed position (see Figure 90 on page 190).6. Slide t

Strany 129 - Fire Suppression Equipment

1. Locate a replacement power cord with the type of plug appropriate for yourgeographical location (see “AC Power, Connection, and Power CordSpecifica

Strany 130 - Electromagnetic Compatibility

NOTE: If the power supply is a redundant power supply in a J6350 Service Router,you can leave the router powered on and power flowing in the other pow

Strany 131 - Router Power Requirements

NOTE: Each power supply must be connected to a dedicated AC power feed. Forinformation about connecting to AC power sources, see “ConnectingPower” on

Strany 132 - Figure 54: AC Plug Types

CAUTION: You must ensure that power connections maintain the proper polarity.The power source cables might be labeled (+) and (–) to indicate their po

Strany 133 - A, and the other power

CAUTION: You must ensure that power connections maintain the proper polarity.The power source cables might be labeled (+) and (–) to indicate their po

Strany 134 - Planning for Power Management

1. Ensure that the voltage across the DC power source cable leads is 0 V and thatthe cable leads cannot become active during installation.CAUTION: You

Strany 135

Product warranties—For product warranty information, visithttp://www.juniper.net/support/warranty/. JTAC Hours of Operation —The JTAC centers have

Strany 136

Figure 94: Installing a DC Power SupplyReplacing Crypto Accelerator Modules on J2320 and J2350 RoutersThe Crypto Accelerator Module is a processor car

Strany 137 - Site Preparation Checklist

Removing a J2320 or J2350 Crypto Accelerator ModuleNOTE: If you are installing a Crypto Accelerator Module into a J2320 or J2350 ServicesRouter for th

Strany 138

Installing a J2320 or J2350 Crypto Accelerator ModuleTo install a Crypto Accelerator Module:1. Take the following steps if you have not already done s

Strany 139 - Chapter 6

8.Press and release the power button to power on the router. Verify that the POWERLED lights steadily.9.Verify that the Crypto Module is correctly ins

Strany 140

Figure 98: Crypto Accelerator Module Location on J4350 and J6350 RoutersTo modify a Crypto Accelerator Module configuration, use the following procedu

Strany 141

6. Locate the Crypto Module on the system board (see Figure 98 on page 202).7. Using a Phillips screwdriver remove the screw, as shown in Figure 99 on

Strany 142

Installing a J4350 or j6350 Crypto Accelerator ModuleTo install a Crypto Accelerator Module:1. Take the following steps if you have not already done s

Strany 143

If Crypto Module appears in the output, the Crypto Accelerator Module is installedcorrectly.Replacing Air Filters on J2350 RoutersThe cooling fans on

Strany 144

Figure 102: Placing the Air Filter on the Air Filter Tray6. Press down on the filter until it is firmly seated against the bottom of the tray.7. Hold

Strany 145 - Chassis Grounding

Figure 104: Attaching Air Filter and Filter CoverWe recommend changing the filter every 6 months. However, the optimal filterreplacement interval can

Strany 146 - Connecting AC Power

Part 1J-series Overview Overview of Services Routers on page 3 System Overview on page 13 PIM and VoIP Module Overview on page 43 Services Router

Strany 147 - Connecting Power ■ 125

208 Replacing Air Filters on J4350 and J6350 RoutersJ2320, J2350, J4350, and J6350 Services Router Getting Started Guide

Strany 148 - Connecting DC Power

Chapter 11Troubleshooting Hardware ComponentsThis chapter contains the following topics: Chassis Alarm Conditions on page 209 Troubleshooting Power

Strany 149 - –48 VDC and RTN

Table 70: Chassis Alarm Conditions and Corrective Actions (continued)Alarm SeverityCorrective ActionAlarm ConditionsComponentRed (major)Replace the fa

Strany 150 - 128 ■ Connecting Power

To bring the PIM online:1. Check if the PIM exceeds the power and heat tokens permitted by issuing theshow chassis fpc and show chassis power-ratings

Strany 151 - POWER LED lights during

user@host# set chassis fpc 2 offlineIf the power and heat tokens no longer exceed the maximum, the PIMs thatwere placed offline by J-series power mana

Strany 152

Chapter 12Contacting Customer Support andReturning HardwareThis chapter describes how to return the Services Router or individual componentsto Juniper

Strany 153 - Chapter 7

The following sections describe the label location on each type of component: J2320 and J2350 Chassis Serial Number and Agency Labels on page 214 J4

Strany 154 - Router Identification

J4350 and J6350 Chassis Serial Number and Agency LabelsJ4350 and J6350 Services Routers have serial number ID labels on the back of thechassis, as sho

Strany 155 - Network Settings

PIM Serial Number LabelPIMs are field-replaceable. Each PIM has a unique serial number. The serial numberlabel is located on the right side of the PIM

Strany 156 - Loopback Address

NOTE: Do not return any component to Juniper Networks unless you have firstobtained an RMA number. Juniper Networks reserves the right to refuse shipm

Strany 157 - Management Access

2 J-series OverviewJ2320, J2350, J4350, and J6350 Services Router Getting Started Guide

Strany 158

Flat-blade screwdriver, approximately 1/4 in. (6 mm) Phillips (+) screwdrivers, numbers 1 and 2Packing the Services Router for ShipmentTo pack the

Strany 159 - 192.168.1.1

When you return components, make sure they are adequately protected withpacking materials and packed so that the pieces are prevented from movingaro

Strany 160

220 Packing a Router or Component for ShipmentJ2320, J2350, J4350, and J6350 Services Router Getting Started Guide

Strany 161 - Connecting to the CLI Locally

Part 4J-series Requirements and Specifications Network Cable Specifications and Connector Pinouts on page 223 Safety and Regulatory Compliance Infor

Strany 162 - ■ Flow control: None

222 J-series Requirements and SpecificationsJ2320, J2350, J4350, and J6350 Services Router Getting Started Guide

Strany 163 - 2. Power on the modem

Chapter 13Network Cable Specifications andConnector PinoutsThe network interfaces supported on the router accept different kinds of networkcable. Ser

Strany 164

Table 71: 2-Port Serial PIM Cables and Connectors (continued)PinoutsEnd-to-EndConductorsConnector HardwareConnectorNameTable 76 on page 228234-40 thre

Strany 165

Table 72: RS-232 DTE Cable Pinout (continued)DescriptionLFH-60 PairingDB-25 PinLFH-60 Pin–––18 to 17RS-232 DCE Cable PinoutTable 73: RS-232 DCE Cable

Strany 166

Table 74: RS-422/449 (EIA-449) DTE Cable Pinout (continued)DescriptionLFH-60 PairingDC-37 (DB-37) PinLFH-60 PinReceive Data (A)261Request to Send (A)4

Strany 167 - Identification

RS-422/449 (EIA-449) DCE Cable PinoutTable 75: RS-422/449 (EIA-449) DCE Cable PinoutDescriptionLFH-60 PairingDC-37 (DB-37) PinLFH-60 PinShield Ground–

Strany 168

Chapter 1Overview of Services RoutersJ-series Services Routers provide stable, reliable, and efficient IP routing, WAN andLAN connectivity, and manage

Strany 169

EIA-530A DTE Cable PinoutTable 76: EIA-530A DTE Cable PinoutDescriptionLFH-60 PairingDB-25 PinLFH-60 PinShield Ground–115Transmit Data (A)59260Receive

Strany 170 - Configurations on page 150

EIA-530A DCE Cable PinoutTable 77: EIA-530A DCE Cable PinoutDescriptionLFH-60 PairingDB-25 PinLFH-60 PinShield Ground–115Transmit Data (A)221Receive D

Strany 171

V.35 DTE Cable PinoutTable 78: V.35 DTE Cable PinoutDescriptionLFH-60 PairingM/34 PinLFH-60 PinFrame Ground–A15Signal Ground–B57Request to Send–C48Cle

Strany 172 - Verifying Basic Connectivity

V.35 DCE Cable PinoutTable 79: V.35 DCE Cable PinoutDescriptionLFH-60 PairingM/34 PinLFH-60 PinFrame Ground–A15Signal Ground–B57Request to Send–C37Cle

Strany 173

Table 80: X.21 DTE Cable Pinout (continued)DescriptionLFH-60 PairingDB-15 PinLFH-60 PinTransmit Data (A)59260Control (A)47348Receive (A)241Indicate (A

Strany 174

Table 81: X.21 DCE Cable Pinout (continued)DescriptionLFH-60 PairingDB-15 PinLFH-60 PinIndicate (B)481247Signal Element Timing (B)521351–––30 to 29Fas

Strany 175 - Configuring Secure Web Access

Table 83: Gigabit Ethernet uPIM RJ-45 Connector Pinout (continued)FunctionSignal NamePinBidirectional pair +BBI_DB+3Bidirectional pair +CBI_DC+4Bidire

Strany 176 - Secure Web Access Overview

Table 85: RJ-45 Chassis Console Connector PinoutDescriptionSignalPinRequest to SendRTS Output1Data Terminal ReadyDTR Output2Transmit DataTxD Output3Ch

Strany 177 - Generating SSL Certificates

Table 87 on page 236 through Table 90 on page 237 describe the RJ-48 connectorpinouts.Table 87: RJ-48 Connector to RJ-48 Connector (Straight) PinoutSi

Strany 178

Table 89: RJ-48 Connector to DB-15 Connector (Straight) PinoutSignalDB-15 Pin(Data NumberingForm)RJ-48 Pin (on T1/E1 PIM)(Data Numbering Form)RX/Ring/

Strany 179

an external compact flash and two universal serial bus (USB) ports for external storage,and an optional Crypto Accelerator Module.J2320 routers ordere

Strany 180 - [edit] hierarchy level, enter

Table 90: RJ-48 Connector to DB-15 Connector (Crossover) Pinout (continued)SignalDB-15 Pin(Data NumberingForm)RJ-48 Pin (on T1/E1 PIM)(Data Numbering

Strany 181 - Verifying Secure Web Access

ISDN RJ-45 Connector PinoutThe 1-port and 4-port ISDN PIMs use an RJ-45 cable, which is not supplied with thePIMs. Table 92 on page 239 describes the

Strany 182

NOTE: Two different RJ-45 cables and RJ-45 to DB-9 adapters are provided. Do notuse the RJ-45 cable and adapter for the Services Router console port t

Strany 183 - Chapter 9

TIM508 Connector PinoutThe TIM508 Analog Telephony Interface Module uses a B25A unshielded 25–pairamphenol cable. Table 95 on page 241 describes the T

Strany 184 - License Key Components

Table 96: TIM510 RJ-45 Connector Pinout (continued)SignalPinNo connection3R1 - Transmit4T1 - Transmit5No connection6No connection7No connection8TIM514

Strany 185

Table 98: TIM516 Connector Pinout (continued)SignalPinTip4Tip5Tip6Tip7Tip8Tip17Tip18Tip19Tip20Tip21Tip22Tip23Tip24Ring26Ring27Ring28Ring29Ring30Ring31

Strany 186

Table 98: TIM516 Connector Pinout (continued)SignalPinRing48Ring49TIM518 Connector PinoutThe TIM518 Analog Telephony Interface Module uses a B25A unsh

Strany 187

Table 99: TIM518 Connector Pinout (continued)SignalPinTip29Tip30Tip31Tip3233Tip42Tip4344Tip45Tip46Tip47Tip48Tip49TIM521 Connector PinoutThe TIM521 Tel

Strany 188 - Displaying Installed Licenses

246 Connector Pinouts for Avaya VoIP ModulesJ2320, J2350, J4350, and J6350 Services Router Getting Started Guide

Strany 189 - Displaying License Usage

Chapter 14Safety and Regulatory ComplianceInformationTo install and use the Services Router safely, follow proper safety procedures. Thischapter discu

Strany 190

upgraded to 1 GB. For instructions on upgrading memory, see “Replacing DRAMModules” on page 188.Each J2350 chassis contains four built-in Gigabit Ethe

Strany 191

risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukkente voorkomen.WARNING: Varoitus Tämä varoitusmerkki merkitsee vaar

Strany 192

entraña la corriente eléctrica y familiarizarse con los procedimientos estándar deprevención de accidentes.WARNING: Varning! Denna varningssymbol sign

Strany 193 - Replacing Hardware Components

The separate protective earthing terminal provided on this product shall bepermanently connected to earth. Replace fuses only with fuses of the sam

Strany 194 - Removing a PIM

Varning! Denna utrustning ska endast installeras och bytas ut av utbildad ochkvalificerad personal.Preventing Electrostatic Discharge DamageMany Servi

Strany 195 - Replacing a PIM ■ 173

Electrical Safety Guidelines and WarningsWhen working on equipment powered by electricity, follow the guidelines describedin the following sections:

Strany 196 - Installing a PIM

Install the Services Router in compliance with the following local, national, orinternational electrical codes: United States—National Fire Protect

Strany 197 - Installing PIM Cables

The cores in the mains lead are colored in accordance with the following code(within the United States): Green and yellow—Earth Blue—Neutral Brow

Strany 198

NOTE: Primary overcurrent protection is provided by the building circuit breaker.This breaker should protect against excess currents, short circuits,

Strany 199

huolehtivassa kojetaulussa sijaitseva suojakytkin, käännä suojakytkinKATKAISTU-asentoon ja teippaa suojakytkimen varsi niin, että se pysyyKATKAISTU-as

Strany 200

DC Power Grounding Requirements and WarningAn insulated grounding conductor that is identical in size to the grounded andungrounded branch circuit sup

Strany 201

The J4350 Services Router supports the following field-replaceable PIMs and AvayaVoIP modules: Gigabit Ethernet uPIM (1-port, 6-port, 8-port, and 16-

Strany 202

WARNING: Waarschuwing De juiste bedradingsvolgorde verbonden is aarde naaraarde, +RTN naar +RTN, en –48 V naar – 48 V. De juiste bedradingsvolgordelos

Strany 203

conectar siempre primero y desconectar por último. Observe que el alambre de tierrase debe conectar siempre primero y desconectar por último.WARNING:

Strany 204

WARNING: Warnung Wenn Litzenverdrahtung erforderlich ist, sind zugelasseneVerdrahtungsabschlüsse, z.B. für einen geschlossenen Regelkreis oder gabelfö

Strany 205

Waarschuwing Deze apparatuur hoort geaard te worden Zorg dat de host-computertijdens normaal gebruik met aarde is verbonden.Varoitus Tämä laitteisto o

Strany 206

Multiple Power Supplies Disconnection WarningWARNING: The J6350 Services Router has more than one power supply connection.All connections must be remo

Strany 207

WARNING: Varning! Denna J6350 enhet har mer än en strömförsörjningsanslutning;alla anslutningar måste vara helt avlägsnade innan strömtillförseln till

Strany 208 - Replacing USB Storage Devices

WARNING: ¡Atención! Antes de manipular el chasis de un equipo o trabajar cercade una fuente de alimentación, desenchufar el cable de alimentación en

Strany 209

WARNING: ¡Atención! El equipo está diseñado para trabajar con sistemas dealimentación tipo TN.WARNING: Varning! Enheten är konstruerad för användning

Strany 210 - Replacing DRAM Modules

WARNING: ¡Atención! Para reducir el riesgo de incendios, usar sólo líneas detelecomunicaciones de calibre No. 26 AWG o más gruesas.WARNING: Varning! F

Strany 211 - Removing a DRAM Module

Warnung Lesen Sie die Installationsanweisungen, bevor Sie das System an dieStromquelle anschließen.WARNING: Avvertenza Consultare le istruzioni di ins

Strany 212 - Installing a DRAM Module

The J6350 Services Router supports the following field-replaceable PIMs and AvayaVoIP modules: Gigabit Ethernet uPIM (1–port, 6-port, 8-port, and 16-

Strany 213

De Juniper Networks router moet in een stellage worden geïnstalleerd die aaneen bouwsel is verankerd. Dit toestel dient onderaan in het rek gemonte

Strany 214 - POWER LED to turn off

WARNING: Warnung Zur Vermeidung von Körperverletzung beim Anbringen oderWarten dieser Einheit in einem Gestell müssen Sie besondere Vorkehrungen treff

Strany 215

Ved montering av denne enheten i et kabinett som er delvis fylt, skal kabinettetlastes fra bunnen og opp med den tyngste komponenten nederst i kabin

Strany 216

försiktighetsåtgärder för att försäkra dig om att systemet står stadigt. Följande riktlinjerges för att trygga din säkerhet: Juniper Networks router

Strany 217 - Removing a DC Power Supply

Observe the following guidelines and warnings: General Laser Safety Guidelines on page 272 Class 1 Laser Product Warning on page 272 Class 1 LED Pr

Strany 218 - Installing a DC Power Supply

Class 1 LED Product WarningWARNING: Class 1 LED product.Waarschuwing Klasse 1 LED-product.Varoitus Luokan 1 valodiodituote.Attention Alarme de produit

Strany 219

WARNING: Warnung Nicht direkt in den Strahl blicken und ihn nicht direkt mitoptischen Geräten prüfen.WARNING: Avvertenza Non fissare il raggio con gli

Strany 220

WARNING: Attention Des radiations invisibles à l'il nu pouvant traverser l'ouverturedu port lorsqu'aucun câble en fibre optique n'

Strany 221

Battery Handling WarningWARNING: Replacing the battery incorrectly might result in an explosion. Replacethe battery only with the same or equivalent t

Strany 222

WARNING: ¡Atención! Existe peligro de explosión si la batería se reemplaza demanera incorrecta. Reemplazar la batería exclusivamente con el mismo tipo

Strany 223

End User License AgreementREAD THIS END USER LICENSE AGREEMENT (“AGREEMENT”) BEFORE DOWNLOADING, INSTALLING, OR USING THE SOFTWARE. BY DOWNLOADING,INS

Strany 224

Table 5: Summary of J-series Features and License Requirements (continued)Separate LicenseJ-series FeatureFeature CategoryOpen Shortest Path First (OS

Strany 225

WARNING: Avvertenza Prima di intervenire su apparecchiature collegate alle lineedi alimentazione, togliersi qualsiasi monile (inclusi anelli, collane,

Strany 226

WARNING: Varoitus Älä työskentele järjestelmän parissa äläkä yhdistä tai irrotakaapeleita ukkosilmalla.WARNING: Attention Ne pas travailler sur le sys

Strany 227

waar de maximale aanbevolen omgevingstemperatuur van 40οC wordt overschreden.Om te voorkomen dat de luchtstroom wordt beperkt, dient er minstens 15,2

Strany 228

temperatura ambiente máxima recomendada de 40οC. Para impedir la restricciónde la entrada de aire, deje un espacio mínimo de 15,2 cm alrededor de las

Strany 229

WARNING: Aviso A descartagem final deste produto deverá ser efectuada de acordocom os regulamentos e a legislação nacional.WARNING: ¡Atención! El dese

Strany 230

EN 61000-3-2 Power Line Harmonics EN 61000-3-3 Voltage Fluctuations and Flicker EN 61000-4-2 ESD EN 61000-4-3 Radiated Immunity EN 61000-4-4 EFT

Strany 231 - Chapter 11

CanadaThis Class B digital apparatus complies with Canadian ICES-003.Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.T

Strany 232

European CommunityCompliance Statements for EMC Requirements 285Chapter 14: Safety and Regulatory Compliance Information

Strany 233

JapanThe preceding translates as follows:This is a Class B product based on the standard of the Voluntary Control Council forInterference by Informati

Strany 234

United StatesThe Services Router has been tested and found to comply with the limits for a ClassB digital device, pursuant to Part 15 of the FCC Rules

Strany 235 - Returning Hardware

Table 5: Summary of J-series Features and License Requirements (continued)Separate LicenseJ-series FeatureFeature CategoryEthernet: Media access contr

Strany 236

If trouble is experienced with this equipment or for repair or warranty information,please follow the applicable procedures explained in the “Technica

Strany 237

Part 5Index Index on page 291Index 289

Strany 238 - Return Procedure

290 IndexJ2320, J2350, J4350, and J6350 Services Router Getting Started Guide

Strany 239 - Tools and Parts Required

IndexSymbols#, comments in configuration statements...xviii#, configuration mode command prompt...93( ), in syntax desc

Strany 240

alternative boot media See boot devices; USBaltitude requirement...106analog media module See TIM514ana

Strany 241

Commit (J-Web configuration editor)...89OK (J-Web configuration editor)...88OK (Quick Configuration)...

Strany 242

command promptschanging...98configuration mode (#)...

Strany 243

Ddaemons See processes, softwaredatasheets URL...43DB-9 connector pinoutschassis console port

Strany 244

earthquakesrack-mount requirements...105seismic requirements...106EIA-530A DCE

Strany 245 - Connector Pinouts

for autoinstallation...134management interface...134Gigabit Ethernet e

Strany 246 - RS-232 DTE Cable Pinout

Table 5: Summary of J-series Features and License Requirements (continued)Separate LicenseJ-series FeatureFeature CategoryCommon CriteriaSecurityNetwo

Strany 247 - RS-232 DCE Cable Pinout

immunity standards...282initial configuration requirements...136injury, ste

Strany 248

hardware...13, 26installation...119interfa

Strany 249

Dual-Port Serial PIM...55Dual-Port T1 PIM...56E3 PIM...

Strany 250 - EIA-530A DTE Cable Pinout

ALM (TGM550 alarm)...72ALM (TIM508 alarm)...74ALM (TIM510 alarm)...

Strany 251 - EIA-530A DCE Cable Pinout

DC power cable, replacing...194DRAM modules...188external compact flash

Strany 252 - V.35 DTE Cable Pinout

PIMs (Physical Interface Modules)4-Port Fast Ethernet...614-Port ISDN BRI...

Strany 253 - X.21 DTE Cable Pinout

powerAC power See AC powerapplying...129button...

Strany 254 - X.21 DCE Cable Pinout

tools and parts required...171USB storage device...186request chassis pic

Strany 255 - Gigabit Ethernet uPIM ports

read installation instructions...266telecommunications cord...265TN power system...

Strany 256 - Chassis Console Port Pinouts

show chassis routing-engine commandchecking CPU temperature...25, 38checking DRAM amount...18,

Strany 257 - E1 and T1 RJ-48 Cable Pinouts

Table 5: Summary of J-series Features and License Requirements (continued)Separate LicenseJ-series FeatureFeature CategorySystem logActivity Logging a

Strany 258

system overviewhardware...13software...

Strany 259

trunk ports, TIM508pinouts...241TRUNK ports, TIM514...

Strany 260

signaling limitations...108suppressing electromagnetic interference(EMI)...

Strany 261 - TGM550 Console Port Pinouts

12 J-series Software Features and LicensesJ2320, J2350, J4350, and J6350 Services Router Getting Started Guide

Strany 262

Chapter 2System OverviewJ-series J2320, J2350, J4350, and J6350 Services Routers have chassis that are similarbut with important differences. J2320, J

Strany 263 - TIM510 RJ-45 Connector Pinout

In addition to the components described in subsequent sections, the chassis includesthe following components: Mounting brackets—One pair of metal bra

Strany 264 - TIM516 Connector Pinout

Figure 2: Front of J2350 ChassisFigure 3: Rear of J2320 ChassisFigure 4: Rear of J2350 AC-Powered ChassisJ2320 and J2350 Services Router Hardware Feat

Strany 265

Figure 5: Rear of J2350 DC-Powered ChassisFigure 6: J2320 Hardware Components16 J2320 and J2350 Services Router Hardware FeaturesJ2320, J2350, J4350

Strany 266 - TIM518 Connector Pinout

Figure 7: J2350 Hardware ComponentsTable 6 on page 17 summarizes the physical specifications for the router chassis.Table 6: J2320 and J2350 Physical

Strany 267 - TIM521 Connector Pinout

7. Ownership. Juniper and Juniper's licensors, respectively, retain ownership of all right, title, and interest (including copyright) in and to t

Strany 268

J2320 and J2350 MidplaneThe J2320 and J2350 midplane is located in the center of the chassis and forms therear of the PIM card cage (see Figure 6 on p

Strany 269 - Information

J2320 and J2350 Boot DevicesJ2320 and J2350 Services Routers can boot from three devices: Internal compact flash External compact flash (also known

Strany 270

STATUS LED on page 21 ALARM LED on page 21 HA LED on page 22 RESET CONFIG Button on page 22 Built-In Gigabit Ethernet Ports on page 23 Console

Strany 271

Table 7: J2320 and J2350 POWER LEDDescriptionStateColorPower is functioning correctly.On steadilyGreenPower button has been pressed and quickly releas

Strany 272 - Qualified Personnel Warning

Table 9: J2320 and J2350 ALARM LEDDescriptionStateColorMajor alarm indicates a critical situation on the router thathas resulted from one of the follo

Strany 273

You can change the default behavior of the RESET CONFIG button. For moreinformation, see the J-series Services Router Basic LAN and WAN Access Configu

Strany 274

USB PortThe USB ports on the front panel of the router (see Figure 8 on page 19 andFigure 9 on page 19) accept a USB storage device or USB storage dev

Strany 275

The AC power supply has a single AC appliance inlet that requires a dedicated ACpower feed. The DC power supply has a terminal block that provides a s

Strany 276

Figure 11: Airflow Through the J2320 ChassisFigure 12: Airflow Through the J2350 ChassisJ4350 and J6350 Services Router Hardware FeaturesThis section

Strany 277

J6350 Power System on page 37 J4350 and J6350 Cooling System on page 38J4350 and J6350 ChassisThe J4350 and J6350 chassis is a rigid sheet metal st

Strany 278

Abbreviated Table of ContentsAbout This Guide xvPart 1 J-series OverviewChapter 1 Overview of Services Routers 3Chapter 2 System Overview 13Chapter 3

Strany 279

Figure 13: Front of J4350 and J6350 ChassisFigure 14: Rear of J4350 AC-Powered ChassisNOTE: The J4350 AC-powered chassis has a power switch and does n

Strany 280

Figure 16: Rear of J4350 DC-Powered ChassisFigure 17: Rear of DC-Powered J6350 ChassisJ4350 and J6350 Services Router Hardware Features 29Chapter 2:

Strany 281

Figure 18: J4350 and J6350 Hardware ComponentsTable 11 on page 30 summarizes the physical specifications for the router chassis.Table 11: J4350 and J6

Strany 282 - Grounded Equipment Warning

J4350 and J6350 MidplaneThe midplane is located in the center of the chassis and forms the rear of the PIMcard cage (see Figure 18 on page 30). You in

Strany 283

J4350 and J6350 Front PanelThe front panel of the Services Router (see Figure 19 on page 32) allows you to installor remove PIMs, view router status L

Strany 284

Figure 20: Slot Number Diagram on Front PanelGigabit Ethernet and 4-port Fast Ethernet ePIMs can be installed in high-speed slotsonly. High-speed slot

Strany 285 - Power Disconnection Warning

off and on again, we recommend waiting a few seconds between shutting it downand powering it back up. Table 13 on page 34 describes the STATUS LED.Tab

Strany 286 - TN Power Warning

RESET CONFIG ButtonUse the RESET CONFIG button to return the router to either the rescue configurationor the factory default configuration. The button

Strany 287

Console PortYou can use the console port on the chassis front panel to connect to the RoutingEngine through an RJ-45 serial cable. From the chassis co

Strany 288 - Chassis Lifting Guidelines

Table 16: Power Supply LEDDescriptionStateNo power is flowing to the power supply.OffPower supply is connected and power is flowing.GreenPower supply

Strany 289

vi J2320, J2350, J4350, and J6350 Services Router Getting Started Guide

Strany 290

WARNING: DC-powered Services Routers are intended for installation only in arestricted access location.J4350 and J6350 Cooling SystemThe cooling syste

Strany 291

Figure 21: Airflow Through the J4350 and J6350 ChassisSoftware OverviewEach J-series Services Router runs the JUNOS software on its general-purposepro

Strany 292

Routing Engine and Packet Forwarding EngineA Services Router has two primary software processing components: Routing Engine—The Routing Engine provid

Strany 293 - Ramp Warning

Table 17: JUNOS Software ProcessesDescriptionNameProcessManages the Services Router system as follows: Provides communication between the other proces

Strany 294 - Class 1 Laser Product Warning

For more information, see “Services Router User Interface Overview” on page 81.Other user interfaces for the Services Router interact with the managem

Strany 295 - Laser Beam Warning

Chapter 3PIM and VoIP Module OverviewJ-series Services Routers accept Physical Interface Modules (PIMs) and Avaya VoIPmodules in the slots on the fron

Strany 296

Table 18: PIM and VoIP Module TermsDefinitionTermITU-T Standard G.992.1 that defines how ADSL works over plain old telephone service(POTS) lines.ADSL

Strany 297

Table 18: PIM and VoIP Module Terms (continued)DefinitionTermStateless firewall filter that enables dial-on-demand routing backup when applied toa phy

Strany 298 - Battery Handling Warning

Field-Replaceable PIMsPIMs are removable and insertable only when the Services Router is powered off.You can install a PIM into one of the slots in th

Strany 299 - Jewelry Removal Warning

Table 19: J2320 and J2350 Field-Replaceable PIM SummarySample Interface Name(type-pim/0/port)Port NumberingSupported Software Releasesfor This PIMPIMg

Strany 300 - Lightning Activity Warning

Table of ContentsAbout This Guide xvObjectives ...x

Strany 301 - Operating Temperature Warning

Table 20: J4350 and J6350 Field-Replaceable PIM and Module SummarySample Interface Name(type-pim/0/port)Slot and Port NumberingSupported Software Rele

Strany 302

Table 20: J4350 and J6350 Field-Replaceable PIM and Module Summary (continued)Sample Interface Name(type-pim/0/port)Slot and Port NumberingSupported S

Strany 303 - Product Disposal Warning

Figure 23: 6-Port Gigabit Ethernet uPIMThe 8-port and 16-port Gigabit Ethernet uPIMs, shown in Figure 24 on page 50 andFigure 25 on page 50, have RJ-4

Strany 304 - Agency Approvals

1000Base-SX, 1000Base-LX, and 1000Base-T SFPs. They do not support1000Base-LH SFPs.1000Base-SX and 1000Base-LX SFP transceivers have the following cha

Strany 305 - Lithium Battery

For alarms, see the configuring and monitoring alarms information in the J-seriesServices Router Administration Guide.Optical Interface Support. Table

Strany 306

Figure 27: SFP Gigabit Ethernet ePIMFeatures. The Gigabit Ethernet ePIM provides the following key features: Autonegotiation through medium-dependent

Strany 307 - European Community

NOTE: High-speed slots are labeled with an E on the front-panel slot number diagram.To install or remove a PIM, see “Replacing a PIM” on page 172.Inte

Strany 308

Dual-Port Serial PIMThe Dual-Port Serial PIM (Figure 28 on page 55) provides a physical connection toserial network media types through two serial int

Strany 309 - United States

Dual-Port T1 or E1 PIMThe Dual-Port T1 PIM (Figure 29 on page 56) and Dual-Port E1 PIM(Figure 30 on page 56) provide a physical connection to T1 or E1

Strany 310

Table 26: Status LEDs for T1 and E1 PortsDescriptionStateColorOnline with no alarms or failures.On steadilyGreenActive with a local alarm. The router

Strany 311 - Index on page 291

J2320 Power System ...24J2350 Power System ...

Strany 312 - 290 ■ Index

Maximum MTU value of 4500 bytes (for channelized T1 or E1 interface) and4098 bytes (for ISDN PRI services)NOTE: For a clear-channel T1 or E1 interfa

Strany 313 - Index ■ 291

For alarms, see the configuring and monitoring alarms information in the J-seriesServices Router Administration Guide.T3 or E3 PIMThe T3 (also known a

Strany 314 - 292 ■ Index

Table 28: Status LEDs for T3 and E3 PortsDescriptionStateColorOnline with no alarms or failures.On steadilyGreenActive with a local alarm. The router

Strany 315 - Index ■ 293

Table 29: LEDs for Dual-Port Fast Ethernet PIMDescriptionStateColorLabelOnline and link is active.On steadilyGreen (100 Mbps)Yellow (10 Mbps)LINK/SPEE

Strany 316 - 294 ■ Index

For pinouts of cable connectors for Fast Ethernet ePIMs, see “Fast Ethernet RJ-45Connector Pinout” on page 233.NOTE: 4-port Fast Ethernet ePIMs suppor

Strany 317 - Index ■ 295

Figure 37: ISDN BRI U PIMISDN BRI PIMs provide the following key features: Onboard network processor Bandwidth on demand Dial backup Dial-on-deman

Strany 318 - 296 ■ Index

For alarms, see the configuring and monitoring alarms information in the J-seriesServices Router Administration Guide.ADSL PIMThe ADSL PIM provides a

Strany 319 - Index ■ 297

Table 32: LEDs for ADSL PIMsDescriptionStateColorLabelPIM passed the self-test and is online andoperational.On steadilyGreenONLINEPIM is offline.OffUn

Strany 320 - 298 ■ Index

Local and remote loopback diagnostics ITU-T G.991.2, ITU-T G.994.1, and ITU-T G.997.1 standards complianceNOTE: Payload loopback functionality is n

Strany 321 - Index ■ 299

Avaya VoIP modules are described in the following sections: Avaya VoIP Module Summary on page 67 TGM550 Telephony Gateway Module on page 69 TIM508

Strany 322 - 300 ■ Index

TIM514 Analog Telephony Interface Module ...75TIM516 Analog Telephony Interface Module ...

Strany 323 - Index ■ 301

Table 34: J2320 and J2350 Avaya VoIP Module Summary (continued)Sample InterfaceName(type-pim/0/port)Maximum Number on aChassisSlot and PortNumberingS

Strany 324 - 302 ■ Index

Table 35: J4350 and J6350 Avaya VoIP Module Summary (continued)Sample InterfaceName(type-pim/0/port)Maximum Number on aChassisSlot and PortNumberingSo

Strany 325 - Index ■ 303

Figure 41: TGM550 Telephony Gateway ModuleThe TGM550 provides the following key features: Voice VoIP Media Gateway services. Two analog telephone (L

Strany 326 - 304 ■ Index

Table 36 on page 71 lists the maximum number of media servers, telephones, andso on that are supported by the TGM550 installed on a J4350 or J6350 or

Strany 327 - Index ■ 305

Table 36: TGM550 Maximum Media Gateway Capacities (continued)Additional InformationTGM550 Maximum CapacityHardware or Feature—800Busy Hour Call Comple

Strany 328 - 306 ■ Index

For more information about the TGM550, see the Avaya manual Hardware Descriptionand Reference for Avaya Communication Manager.TIM508 Analog Telephony

Strany 329 - Index ■ 307

TIM508 LEDs indicate link status and activity. Table 39 on page 74 describes themeaning of the LEDs.Table 39: LEDs for TIM508DescriptionStateColorLabe

Strany 330 - 308 ■ Index

To install or remove an Avaya VoIP module, see “Replacing a PIM” on page 172.TIM510 LEDs indicate link status and activity. Table 40 on page 75 descri

Strany 331 - Index ■ 309

Table 41: TIM514 Possible Port ConfigurationsPossible Analog Trunk (TRUNK) Port ConfigurationsPossible Analog Telephone (LINE) PortConfigurationsLoop-

Strany 332 - 310 ■ Index

Figure 45: TIM516 Analog Telephony Interface Module615MITATCSENILSENIL71—421—8MLAgolanA668300gSENILYou can configure TIM516 lines as described in Tabl