Juniper-networks Juniper M-series M10i Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware Juniper-networks Juniper M-series M10i. Juniper Networks Juniper M-series M10i User Manual [it] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 78
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
M10i Internet Router
PIC Guide
Juniper Networks, Inc.
1194 North Mathilda Avenue
Sunnyvale, California 94089
USA
408-745-2000
www.juniper.net
Part Number: 530-022504-01, Revision 2
Zobrazit stránku 0
1 2 3 4 5 6 ... 77 78

Shrnutí obsahu

Strany 1 - PIC Guide

M10i Internet RouterPIC GuideJuniper Networks, Inc.1194 North Mathilda AvenueSunnyvale, California 94089USA408-745-2000www.juniper.netPart Number: 530

Strany 2

10 ft (3.05 m) posilock SMB to BNC (provided) Four pairs of Rx and Tx coaxial cablesCables and connectorsOne tricolor per port: Off—Not enabled Green

Strany 3

ATM2 E3 IQ PIC JUNOS 6.1 and laterSoftware release Two E3 ports Power requirement: 0.41 A @ 48 V (20 W) Intelligent queuing (IQ) PICs support fine-gra

Strany 4 - SONET/SDH

One tricolor per port: Off—Not enabled Green—Online with no alarms or failures Amber—Online with alarms for remote failures Red—Active with a local al

Strany 5 - Adaptive Services II PIC

ATM2 OC3/STM1 IQ PIC JUNOS 6.1 and laterSoftware release Two OC3 ports Power requirement: 0.41 A @ 48 V (20 W) Intelligent queuing (IQ) PICs support f

Strany 6 - 6 ■ Adaptive Services II PIC

Circuit cross-connect (CCC) for leveraging ATM access networks User-configurable virtual circuit (VC) and virtual path (VP) support Support for idle

Strany 7 - Adaptive Services II FIPS PIC

Table 3: Optical Interface Support for ATM2 OC3 IQ PICs (continued)MultimodeIntermediate Reach (IR)ParameterMultivendor agreementTelcordia GR-253Stand

Strany 8

ATM2 OC12/STM4 IQ PIC JUNOS 6.1 and laterSoftware release One OC12 port Power requirement: 0.41 A @ 48 V (20 W) Intelligent queuing (IQ) PICs support

Strany 9 - ATM2 DS3 IQ PIC

Duplex SC/PC connector (Rx and Tx) Optical interface support—See Table 4 on page 17Cables and connectorsOne tricolor per port: Off—Not enabled Green—

Strany 10 - 10 ■ ATM2 DS3 IQ PIC

Channelized DS3 IQ PIC JUNOS 6.1 and laterSoftware release Four DS3 ports Power requirement: 0.32 A @ 48 V (15.6 W) Intelligent queuing (IQ) PICs supp

Strany 11 - ATM2 E3 IQ PIC

One tricolor per port: Off—Not enabled Green—Online with no alarms or failures Amber—Online with alarms for remote failures Red—Active with a local al

Strany 12 - 12 ■ ATM2 E3 IQ PIC

This guide provides an overview and description of the Physical Interface Cards (PICs)supported by the Juniper Networks M10i Internet router. The PICs

Strany 13 - ATM2 OC3/STM1 IQ PIC

Channelized E1 IQ PIC JUNOS 6.1 and laterSoftware release Ten E1 ports Power requirement: 0.15 A @ 48 V (7.2 W) Intelligent queuing (IQ) PICs support

Strany 14 - 14 ■ ATM2 OC3/STM1 IQ PIC

Alarm indication signal (AIS) Loss of frame (LOF) Out of frame (OOF) Failed signal rate (FSR)Alarms, errors, andevents Layer 2 per-queue and per-chan

Strany 15 - ATM2 OC3/STM1 IQ PIC ■ 15

Channelized OC12 PIC JUNOS 6.1 and laterSoftware release One OC12 port Power requirement: 0.23 A @ 48 V (10.8 W) 12 DS3 channels Supports IP version 4

Strany 16 - ATM2 OC12/STM4 IQ PIC

Alarm indication signal (AIS-L, AIS-P) BERT functionality (you can configure one DS3 channel in BERT mode and configure theremaining channels to tran

Strany 17 - ATM2 OC12/STM4 IQ PIC ■ 17

Channelized OC12 IQ PIC JUNOS 6.1 and laterSoftware release One OC12 port Power requirement: 0.23 A @ 48 V (10.8 W) Intelligent queuing (IQ) PICs supp

Strany 18 - Channelized DS3 IQ PIC

One tricolor per port: Off—Not enabled Green—Online with no alarms or failures Amber—Online with alarms for remote failures Red—Active with a local al

Strany 19 - Channelized DS3 IQ PIC ■ 19

Channelized OC3 IQ PIC JUNOS 7.6 and laterSoftware release One OC3 port Power requirement: 0.39 A @ 48 V (18.6 W) Intelligent queuing (IQ) PICs suppor

Strany 20 - Channelized E1 IQ PIC

One tricolor per port: Off—Not enabled Green—Online with no alarms or failures Amber—Online with alarms for remote failures Red—Active with a local al

Strany 21 - Channelized E1 IQ PIC ■ 21

Channelized STM1 IQ PIC JUNOS 6.1 and laterSoftware release One STM1 port Power requirement: 0.39 A @ 48 V (18.6 W) Intelligent queuing (IQ) PICs supp

Strany 22 - Channelized OC12 PIC

Alarm indication signal (AIS-L, AIS-P) Bit error rate signal degrade (BERR-SD), bit error rate signal fail (BERR-SF) Bit interleaved parity errors B1

Strany 23 - Channelized OC12 PIC ■ 23

Table 1: PICs Supported in the M10i Internet RouterPagePICSlots RequiredFirst JUNOSSupportPortsPIC Family and TypeATM2 IQ91 slot6.14ATM2 DS3 IQ111 slo

Strany 24 - Channelized OC12 IQ PIC

Channelized T1 IQ PIC JUNOS 7.4 and laterSoftware release Ten T1 ports Power requirement: 0.15 A @ 48 V (7.2 W) Intelligent queuing (IQ) PICs support

Strany 25 - Channelized OC12 IQ PIC ■ 25

Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection(RED), weighted random early detection (WRED) SNMP: T1 MIB an

Strany 26 - Channelized OC3 IQ PIC

DS3 PIC JUNOS 6.1 and laterSoftware release Two or four DS3 ports Power requirement: 0.47 A @ 48 V (22.5 W) Integrated DSU interoperability with leadi

Strany 27 - Channelized OC3 IQ PIC ■ 27

One tricolor per port: Off—Not enabled Green—Online with no alarms or failures Amber—Online with alarms for remote failures Red—Active with a local al

Strany 28 - Channelized STM1 IQ PIC

E1 PIC JUNOS 6.1 and laterSoftware release Four E1 or coaxial ports Power requirement: 0.08 A @ 48 V (3.74 W) Two versions: 4-port, 120-ohm, RJ-48 4-p

Strany 29 - Channelized STM1 IQ PIC ■ 29

One tricolor per port: Off—Not enabled Green—Online with no alarms or failures Amber—Online with alarms for remote failures Red—Active with a local al

Strany 30 - Channelized T1 IQ PIC

E3 PIC JUNOS 6.0 and laterSoftware release Two E3 ports Power requirement: 0.47 A @ 48 V (22.5 W) Integrated DSU interoperabilityDescription High-dens

Strany 31 - Channelized T1 IQ PIC ■ 31

Alarm indication signal (AIS) Equipment failure (does not affect service) Frame error Line code violation Loss of signal (LOS) Out of frame (OOF) Yel

Strany 32 - 32 ■ DS3 PIC

E3 IQ PIC JUNOS 6.1 and laterSoftware release Four E3 ports Power requirement: 0.38 A @ 48 V (18 W) Intelligent queuing (IQ) PICs support fine-grained

Strany 33 - DS3 PIC ■ 33

One tricolor per port: Off—Not enabled Green—Online with no alarms or failures Amber—Online with alarms for remote failures Red—Active with a local al

Strany 34 - 34 ■ E1 PIC

Table 1: PICs Supported in the M10i Internet Router (continued)PagePICSlots RequiredFirst JUNOSSupportPortsPIC Family and TypeEthernet IQ2511 slot7.6R

Strany 35 - E1 PIC ■ 35

EIA-530 PIC JUNOS 6.1 and laterSoftware release Two EIA-530, X.21 or V.35 serial ports Power requirement: 0.07 A @ 48 V (3.4 W)Description Configured

Strany 36 - 36 ■ E3 PIC

Three bicolor per port: Data set ready (DSR): Green—DSR is detected or ignored Red—DSR expected but not present Data carrier detect (DCD): Green—DCD i

Strany 37 - E3 PIC ■ 37

ES PIC JUNOS 6.1 and laterSoftware release High-bandwidth encryption (in accordance with IPSec standards) Power requirement: 0.21 A @ 48 V (10 W) Supp

Strany 38 - E3 IQ PIC

Input and output bytes per tunnel Total authentication failures Total antireply failures Total encryption ASIC errors per PICInstrumentation(counters

Strany 39 - E3 IQ PIC ■ 39

Fast Ethernet PICsLeft: 4-Port Fast Ethernet PIC; Right: 8-Port Fast Ethernet PICLeft: 12-Port Fast Ethernet PIC; Right: VHDCI to RJ-21 cable JUNOS 6.

Strany 40 - EIA-530 PIC

4-port PIC: Connector: Two-pair, Category 5 unshielded twisted-pair connectivity through an RJ-45connector Pinout: MDI noncrossover8-port PIC: Connect

Strany 41 - EIA-530 PIC ■ 41

Table 8: Optical Interface Support for Fast Ethernet PICs (continued)FX interface for 8-PortOptical Parameters62.5/125 micrometer MMF: 1.24 miles /2 k

Strany 42 - 42 ■ ES PIC

Gigabit Ethernet PIC with SFP JUNOS 6.3 and laterSoftware release One Gigabit Ethernet port Power requirement: 0.15 A @ 48 V (7.3 W) Supports large Et

Strany 43 - ES PIC ■ 43

Status LED, one bicolor: Off—PIC is not enabled Green—PIC is operating normally Red—PIC has an error or failurePort LEDs, one pair per port: Link—If g

Strany 44 - Fast Ethernet PICs

Gigabit Ethernet IQ PIC with SFP JUNOS 6.1 and laterSoftware release One Gigabit Ethernet port Power requirement: 0.46 A @ 48 V (22 W) Intelligent que

Strany 45 - Fast Ethernet PICs ■ 45

Adaptive Services II PIC JUNOS 6.4 and laterSoftware release Supports tunnel services. This feature is included with the PIC and does not require anin

Strany 46 - 46 ■ Fast Ethernet PICs

Status LEDs, one tricolor: Off—Not enabled Green—Online with no alarms or failures Amber—Online with alarms for remote failures Red—Active with a loc

Strany 47 - Gigabit Ethernet PIC with SFP

Gigabit Ethernet IQ2 PIC with SFP JUNOS 7.6R3 and laterSoftware release Four Gigabit Ethernet ports Power requirement: 0.65 A @ 48 V (31 W)Description

Strany 48

You can install any transceiver supported by the PIC. For information about installingand removing transceivers, see the PIC and Transceiver Installa

Strany 49

Table 11: Optical Interface Support for Gigabit Ethernet IQ2 PICs with SFP (continued)1000Base-LH1000Base-LX1000Base-SXParameter–3 through +3 dBm–11.5

Strany 50

Link Services PIC JUNOS 6.1 and laterSoftware release Power requirement: 0.17 A @ 48 V (8 W) Three versions: 4 multilink bundles, 256 LFI links 32 mul

Strany 51

MultiServices 100 PIC JUNOS 8.1 and laterSoftware release Supports tunnel services. This feature is included with the PIC and does not require anindiv

Strany 52

Table 12: MultiServices PICs Software Features Supported by the M10i Router (continued)8.1Stateful firewall with packet inspection: detects SYN attack

Strany 53

SONET/SDH OC3c/STM1 PIC JUNOS 6.1 and later (Type 1)NOTE: Although the illustration shows a multimode PIC, both a multimode PIC and asingle-mode inter

Strany 54 - Link Services PIC

SONET alarms: Alarm indication signal—line (AIS-L) Alarm indication signal—path (AIS-P) Bit error rate signal degrade (BERR-SD) Bit error rate signal

Strany 55 - MultiServices 100 PIC

Table 13: Optical Interface Support for SONET/SDH OC3c/STM1 PICs (continued)MultimodeIntermediate ReachParameterMultivendor agreementTelcordia GR-253S

Strany 56 - 56 ■ MultiServices 100 PIC

Table 2: Adaptive Services PICs Software Features (continued)6.4Network Address Translation (NAT) for IP addresses6.4Port Address Translation (PAT) fo

Strany 57 - SONET/SDH OC3c/STM1 PIC

SONET/SDH OC3c/STM1 PIC with SFP JUNOS 8.4 and laterSoftware release Two OC3c ports Power requirement: 0.25 A @ 48 V (12 W)Description Multiplexing an

Strany 58 - 58 ■ SONET/SDH OC3c/STM1 PIC

SONET alarms: Alarm indication signal—line (AIS-L) Alarm indication signal—path (AIS-P) Bit error rate signal degrade (BERR-SD) Bit error rate signal

Strany 59 - SONET/SDH OC3c/STM1 PIC ■ 59

Table 14: Optical Interface Support for SONET/SDH OC3c/STM1 PICs with SFP (continued)Long Reach (LR-1)Intermediate Reach (IR-1)MultimodeParameterSFPSF

Strany 60

SONET/SDH OC3/STM1 (Multi-Rate) PIC with SFP JUNOS 8.4 and laterSoftware release Rate-selectable using one of the following rates: 1-port OC12 1-port

Strany 61

One tricolor per port: Off—Not enabled Green—Online with no alarms or failures Amber—Online with alarms for remote failures Red—Active with a local al

Strany 62

Table 15: Optical Interface Support for SONET/SDH OC3/STM1 (Multi-Rate) PICs with SFP Configured atan OC3/STM1 RateLong Reach (LR-1)Intermediate Reach

Strany 63

SONET/SDH OC12c/STM4 PIC JUNOS 6.1 and laterSoftware release One port Power requirement: 0.23 A @ 48 V (10.8 W)Description Multiplexing and demultiple

Strany 64

SONET alarms: Alarm indication signal—line (AIS-L) Alarm indication signal—path (AIS-P) Bit error rate signal degrade (BERR-SD) Bit error rate signal

Strany 65

Table 17: Optical Interface Support for SONET/SDH OC12c/STM4 PICs (continued)MultimodeIntermediate ReachParameterMultivendor agreementTelcordia GR-25

Strany 66 - SONET/SDH OC12c/STM4 PIC

SONET/SDH OC12/STM4 (Multi-Rate) PIC with SFP JUNOS 8.4 and laterSoftware release Rate-selectable using one of the following rates: 1-port OC3 1-port

Strany 67 - SONET/SDH OC12c/STM4 PIC ■ 67

Adaptive Services II FIPS PIC JUNOS 7.2 and laterSoftware release JUNOS-FIPS requires an Adaptive Services II FIPS PIC for external IPSec connections.

Strany 68 - 68 ■ SONET/SDH OC12c/STM4 PIC

One tricolor per port: Off—Not enabled Green—Online with no alarms or failures Amber—Online with alarms for remote failures Red—Active with a local al

Strany 69

Table 18: Optical Interface Support for SONET/SDH OC12/STM4 (Multi-Rate) PICs with SFP Configured atan OC3/STM1 RateLong Reach (LR-1)Intermediate Reac

Strany 70

SONET/SDH OC48c/STM16 PIC with SFP JUNOS 6.4 and laterSoftware release One OC48 port Power requirement: 0.86 A @ 48 V (41.4 W)Description Multiplexing

Strany 71

One tricolor per port: Off—Not enabled Green—Online with no alarms or failures Amber—Online with alarms for remote failures Red—Active with a local al

Strany 72

Table 20: Optical Interface Support for SONET/SDH OC48c/STM16 PICs with SFPLong Reach (LR)Intermediate Reach (IR)Short Reach (SR)ParameterSingle-mode;

Strany 73

T1 PIC JUNOS 6.1 and laterSoftware release Four T1 ports Power requirement: 0.08 A @ 48 V (3.7 W) Supports clear channel T1 per port (1.544 Mbps per c

Strany 74

Tunnel Services PIC JUNOS 6.1 and laterSoftware release Power requirement: 0.07 A @ 48 V (3.4 W)Description Loopback function that encapsulates and de

Strany 75 - T1 PIC ■ 75

Appendix AHigh Availability FeaturesHigh availability features include Routing Engine redundancy, graceful Routing Engineswitchover (GRES), nonstop br

Strany 76 - Tunnel Services PIC

Copyright © 2008, Juniper Networks, Inc. All rights reserved.Juniper Networks, the Juniper Networks logo, NetScreen, and ScreenOS are registered trade

Strany 77 - High Availability Features

Status LED, one tricolor: Off—PIC is offline and it is safe to remove it from the chassis. Green—PIC is operating normally. Amber—PIC is initializing.

Strany 78

ATM2 DS3 IQ PIC JUNOS 6.1 and laterSoftware release Four DS3 ports Power requirement: 0.41 A @ 48 V (20.0 W) Intelligent queuing (IQ) PICs support fin

Komentáře k této Příručce